| Application | Cell culture | Cell culture | Microbiology | Microbiology |
| Number of parallel units | Up to 24 | Up to 24 | Up to 24 | Up to 24 |
| Software | DASware control, other DASware optional | DASware control, other DASware optional | DASware control, other DASware optional | DASware control, other DASware optional |
| User Interface | Process computer with monitor | Process computer with monitor | Process computer with monitor | Process computer with monitor |
| Typical power consumption (4-fold system without process computer) | 168 W (at 230 V)/ 154 W (at 115 V) | 168 W (at 230 V)/ 154 W (at 115 V) | 168 W (at 230 V)/ 154 W (at 115 V) | 168 W (at 230 V)/ 154 W (at 115 V) |
| Dimensions (W × D × H, 4-fold system without process computer) | 30 x 70 x 49 cm (12 x 28 x 19 in) | 30 x 70 x 49 cm (12 x 28 x 19 in) | 30 x 70 x 49 cm (12 x 28 x 19 in) | 30 x 70 x 49 cm (12 x 28 x 19 in) |
| Typical weight (4-fold system without accessories) | 44 kg | 44 kg | 44 kg | 44 kg |
| Bioreactors | | | | |
| Vessels | Glass vessels | Single-use vessels | Glass vessels | Single-use vessels |
| Sterilization | Autoclavable | Pre-sterilized | Autoclavable | Pre-sterilized |
| Total volume | 350 mL | 380 mL | 350 mL | 380 mL |
| Agitation | | | | |
| Drive | Direct overhead drives | Magnetic overhead drives | Direct overhead drives | Magnetic overhead drives |
| Speed ranges | 20 – 2500 rpm | 20 – 500 rpm | 20 – 2500 rpm | 20 – 2000 rpm |
| Impellers | Marine | Pitched-blade | Rushton-type | Rushton-type |
| Gassing | | | | |
| Gas supply | TMFC; overlay and/or sparger | TMFC; overlay and/or sparger | TMFC; sparger | TMFC; sparger |
| Standard gas flow rates | 0.04 – 5 sL/h, 0.04 – 3.5 sL/h CO2 | 0.04 – 5 sL/h, 0.04 – 3.5 sL/h CO2 | 0.2 – 25 sL/h, 0.2 – 18 sL/h CO2 | 0.2 – 25 sL/h, 0.2 – 18 sL/h CO2 |
| Standard gas mixing | Air, N2, O2 and/or CO2 | Air, N2, O2 and/or CO2 | Air, N2, O2 and/or CO2 | Air, N2, O2 and/or CO2 |
| Feeding | | | | |
| Feed lines per vessel | 2 (standard)/ 4 (optional) | 2 (standard)/ 4 (optional) | 2 (standard)/ 4 (optional) | 2 (standard)/ 4 (optional) |
| Standard feed rates (depending on tube diameter) | 0.3 – 9.5 mL/h to 13 – 420 mL/h | 0.3 – 9.5 mL/h to 13 – 420 mL/h | 0.3 – 9.5 mL/h to 13 – 420 mL/h | 0.3 – 9.5 mL/h to 13 – 420 mL/h |
| Monitoring and Control | | | | |
| Temperature control | Liquid-free heating and cooling (Peltier) | Liquid-free heating and cooling (Peltier) | Liquid-free heating and cooling (Peltier) | Liquid-free heating and cooling (Peltier) |
| Standard temperature range (at 25° C room temp.) | 10 – 60°C | 10 – 45°C | 10 – 60°C | 10 – 45°C |
| pH control | CO2/base, and other set-ups | CO2/base, and other set-ups | Acid and/or base, and other set-ups | Acid and/or base, and other set-ups |
| DO control | Cascade (O2 concentration, gas flow rate), and other set-ups | Cascade (O2 concentration, gas flow rate), and other set-ups | Cascade (agitation speed, O2 concentration, gas flow rate), and other set-ups | Cascade (agitation speed, O2 concentration, gas flow rate), and other set-ups |
| ORP (redox) measurement | - | - | Optional (select redox or level) | Optional (select redox or level) |
| Level/foam | Optional | Optional | Optional (select redox or level) | Optional (select redox or level) |
| OD measurement | Optional (DASGIP OD4) | Optional (DASGIP OD4) | Optional (DASGIP OD4) | Optional (DASGIP OD4) |
| Exhaust condensation | Liquid-free (Peltier) | Liquid-free (Peltier) | Liquid-free (Peltier) | Liquid-free (Peltier) |
| Exhaust analysis | - | - | Optional (DASGIP GA4) | Optional (DASGIP GA4) |